Remote Unit for Data
Acquisition, Management and Control

Flexibility

The flexibility of the EA - 205 as much facilitate their integration in new
systems as in the remodeling of existing installations.

Configuration

Software
and parameters that determine their operation, can be upgraded as much from the local
channel as from the remote channel.

Maintenance

The
equipment construction is based on standard market components using an open hardware and
software architecture, which facilitates its update.

Technical
Specifications

HARDWARE

|
FUNCTIONS

|
CPU
- 386/486/PENTIUM SIMM 1 A 16 MB
MEMORY
- RAM SIMM DE 1 A 16 MB
- PCMCIA SRAM 1 ó 2 MB
- PCMCIA FLASH 4 MB
- ROM/RAM DISK 1.4 MB
COMMUNICATIONS
- LOCAL CHANNEL 19200 BAUDS
- RS232
- REMOTE CHANNEL 1200/2400/4800/9600/19200
- RADIO
- VSAT
- RS485
- RS232
- REAL TIME COMM PROTOCOLS
- EASY ADAPTATION TO USER PROTOCOLS
DATA
DISPLAY
- LOCAL DISPLAY: DISPLAY "IN SITU" SENSOR
VALUES WITH NO NEED TO CONNECTING ANY PERIPHERAL
- LOCAL CHANNEL: ACCESIBLE THROUGH LAPTOP
- REMOTE CHANNEL: BY MEANS COMM FRONT END
REAL
TIME - CLOCK
- DS - 12887 RTC WITH QUARTZ OSCILLATOR AND 10 YEARS LIFE
LITHIUM BATTERY
WATCH
- DOG
- WATCH TIME - DOG DE 0.5 SEG A 16 MIN 48 SEG
DIGITAL
INPUTS
- CARD INPUTS: 16
- INPUT VOLTS: 5 - 24 VDC
- ISOLATION: 2500 VDC
- CARD SIZE: HALF SIZE
- UNTIL 112 CONFIGURABLE INPUTS
DIGITAL
OUTPUT
- OPTOISOLATED OUTPUT OR BY POR RELAY
- CARD OUTPUTS: 8/16
- ISOLATION VOLTS ( OPTOISOLATED OUTPUT ): 2500 VDC
- TELECONTROL BY MEANS LEVELS OR IMPULSE
- UNTIL 112 CONFIGURABLE OUTPUTS
ANALOGICAL
INPUTS
- 12 PRECISION BITS
- SINGLE INPUTS - ENDED O DIFERENCIALES
- BIPOLAR OR UNIPOLAR INPUTS
- 0-5 VDC - 0 - 20 Ma DC
- CARD SIZE: HALF SIZE
- CONFIGURABLE INPUTS : 40 (DIFF), 80 (SE)
CAPACITY
OPTIONS
- ISOLATED SERIE CHANNELS RS485
- REAL TIME DATA DISPLAY
- INTERNAL RADIO MODEM
- HARD DISK AND 3.5" FLOPPY
- LOCAL PRINTER CONNECTION
|
INTRODUCTION
Remote Station EA 205 is designed for tele-waching
and tele-control.
It's totally configurable from local and remote channel.
It's a robust and flexible equipment wide tested in many
instalations:
- Water supply.
- Quality water control.
- Meteorology.
- Electrical Systems.
- Channels Control.
- Purifying Stations Control.
- Tele-alarm.
BASIC FUNCTIONS
ALARM. EA 205 incorporate the following
alarm types:
- Digital: Corresponden a los cambios de estado de
las entradas digitales.
- Analogic: EA 205 detects for each analogic
signal next alarm levels: High, High - High, Low y Low Low. Levels High y Low have
associate factors of independent hysteresys.
- Internal: The
internal alarms are generated by the own EA - 205 when internal failure is detected, which
is notified the Control center.
CONTROL. The
control function allows to act at a distance on any configured digital output.
The control orders act on the outputs establishing an
impulse or a level.
DATA MANAGEMENT. EA
- 205 is equipped with powerful Intel processors that added to the memory that
incorporates confer a high capacity of process.
Basic management functions are:
- Data acquisition
- Alarm and historical files processing.
- Obtaining calculated values.
- Use of inputs, outputs and logic cards.
Other functions:
- Application software update with no need to move.
- Remote access to OS.
- Access control to the equipment environment.
CONFIGURATION. The parameters that determine
EA - 205 operation are configurables from the local and remote channel.
RULES:
- Marcado CE
- Year 2000 compliant
|